Electro Technical including RF Calibration
In Electrical, customers conducting testing/ measurements are dealing with people’s safety and they are carrying an extended duty of care not only ensuring that the equipment’s are safe, but that it is fit for purpose and not posing serious risk to others and public in general.
Electrical instrument calibration involves the use of precise devices that evaluate the performance of key properties for other devices called “Unit Under Calibration” (UUCs). Because these precise devices have thoroughly known performance characteristics compared to the UUC, performance evaluation and/or calibration adjustment of the UUC to identify or minimize errors is possible.
Our Electro-technical calibration services are equipped to calibrate almost every electrical parameter covering basic working level instruments like ammeter / voltmeter to Multifunction calibrators & 8½ digit multimeters.
Offerings | Technical Specification | Description |
---|---|---|
AC High Voltage | 1 kV to 5 kV | Using High voltage probe ( Fluke) with DMM /Direct Method |
AC High Voltage | 5 kV to 10 kV | Using High voltage probe ( Fluke) with DMM /Direct Method |
CAPACITANCE | 1 nF to 1000 nF | Using LCR Q meter ,Model -4910 Make: Aplab ,/direct Method |
INDUCTANCE | 100 µH to 1 H | Using LCR -Q METER make: Aplab Model: 4910 / Direct Method |
AC CURRENT | 2 A to 10 A | Using 51/2, Multifunction calibrator , Make : Zeal , Direct Method |
AC CURRENT | 2 mA to 2000 mA | Using 51/2, Multifunction calibrator , Make : Zeal , Direct Method |
AC CURRENT | 200 µA to 2 mA | Using 51/2, Multifunction calibrator , Make : Zeal , Direct Method |
AC voltage | 200 mV to 200 V | Using 51/2 Multi function calibrator, Zeal Make, Direct Method |
AC voltage | 200 V to 1000 V | Using 51/2 Multi function calibrator, Zeal Make, Direct Method |
AC VOLTAGE | 5 mV to 200 mV | Using 51/2, Multifunction calibrator , Make : Zeal , Direct Method |
AC- High Current | 10 A to 100 A | Using 5 1/2 Digit , Zeal Make, Multifunction calibrator with current coil / Direct Method |
AC- High Current | 100 A to 1000 A | Using 5 1/2 Digit , Zeal Make,Multifunction calibrator with current coil / Direct Method |
DC High Voltage | 1 kV to 5 kV | Using High voltage probe ( Fluke) with DMM /Direct Method |
DC High Voltage | 5 kV to 10 kV | Using High voltage probe ( Fluke) with DMM /Direct Method |
DC Resistance (2 wire) | 1 ohm to 10 ohm | Using 61/2 DMM, Model8846-A, Make : Fluke . Direct Method |
DC Resistance (2 Wire) | 10 ohm to 100 ohm | Using 6 1/2 DMM, Model : 8846-A , Make: Fluke : / Direct method |
DC Resistance (2 Wire) | 100 kohm to 2 Mohm | Using 6 1/2 DMM, Model : 8846-A , Make: Fluke : / Direct method |
DC Resistance (2 Wire) | 100 ohm to 100 kohm | Using 6 1/2 DMM, Model : 8846-A , Make: Fluke : / Direct method |
DC Resistance (2 Wire) | 2 Mohm to 200 Mohm | Using 6 1/2 DMM, Model : 8846-A , Make: Fluke : / Direct method |
Capacitance | 1 nF to 1 µF | Using std. capacitance box( Discrete Method) / Direct Method |
DC CURRENT | 2 A to 9 A | Using 51/2, Multifunction calibrator , Make : Zeal , Direct Method |
DC CURRENT | 2 mA to 2000 mA | Using 51/2, Multifunction calibrator , Make : Zeal , Direct Method |
DC CURRENT | 200 µA to 2 mA | Using 51/2, Multifunction calibrator , Make : Zeal , Direct Method |
DC Resistance | 0.001 ohm to 200 Mohm | Using Std. Resistance Box ( Discrete value) / Direct Method |
DC Voltage | 1 mV to 200 mV | Using 51/2, Multifunction calibrator , Make : Zeal , Direct Method |
DC Voltage | 200 mV to 200 V | Using 51/2, Multifunction calibrator , Make : Zeal , Direct Method |
DC Voltage | 200 V to 1000 V | Using 51/2, Multifunction calibrator , Make : Zeal , Direct Method |
DC- High Current | 10 A to 100 A | Using 5 1/2 Digit , Zeal Make,Multifunction calibrator with current coil / Direct Method |
DC- High Current | 100 A to 900 A | Using 5 1/2 Digit , Zeal Make,Multifunction calibrator with current coil / Direct Method |
Inductance | 1 mH to 1 H | Using Std. Inductance decade box ( Discrete values) By Direct Method |
Frequency | 50 Hz to 200 kHz | Using 6 1/2, DMM, Model : 8846 A, Make: Fluke / Direct Method |
Time Interval | 1 s to 999 s | Using Time calibrator / Direct Method: |
Offerings | Technical Specification | Description |
---|---|---|
AC High Voltage at 50Hz | 1 kV to 5 kV | Using High voltage probe ( Fluke) with DMM /Direct Method |
AC High Voltage at 50Hz | 5 kV to 10 kV | Using High voltage probe ( Fluke) with DMM /Direct Method |
DC High Voltage | 1 kV to 5 kV | Using High voltage probe ( Fluke) with DMM /Direct Method |
DC High Voltage | 5 kV to 10 kV | Using High voltage probe ( Fluke) with DMM /Direct Method |
Time Interval | 1 s to 999 s | Using Time calibrator / Direct Method: |