Medical Equipment Calibration

Medical Equipment Calibration

Medical Equipment Calibration
Medical Equipment Calibration is the process of configuring the measurement and the accuracy of the medical device or the medical system used in Hospitals. This field intends to offer advance healthcare treatment, including diagnosis, monitoring and therapy.

The medical calibration measurements, is important because they establish whether the medical devices are appropriate, according to the international standards or not. The calibration also helps to minimise misdiagnosis caused by poorly calibrated machine. It is very important to configure hospital systems, according to the standard calibration because these machines need to be absolutely accurate since it is a matter of life and death.

View our offerings

OfferingsTechnical SpecificationDescription
BP ApparatusAll Ranges

Manometer and Leak test

Defibrillator Calibration

Calibration of all ranges

Energy, ECG, Charging time and Electrical safety
ECG Machines Calibration

Calibration of all ranges

HV testing, Leakage Current test, Earth Bond, Resistance
Electrosurgical Diathermy (Cautery Machines) Calibration

Calibration of all ranges

Electrical safety test, ESU output Power, Current, Peak to peak voltage, crest factor
Fetal Monitor Calibration

Calibration of all ranges

Electrical safety and IUP
Hemotherm Calibration

Calibration of all ranges

Temperature Calibration

Incubator Analyzer Calibration

Humidity: 30 to 90 %RH
Sound Level: 94 dB
Temperature: 10 to 50 °C
Calibration of Fluke INCU-2
Calibration parameters Pressure, Flow rate, TIME, Temperature, RH, Airflow
Infusion Pump Analyzer Calibration

Flow Rate: 10 ml/hr. to 1000 ml/hr.
Flow Volume: 5 ml to 400 ml
Calibration of Fluke IDA1-S,
IDA4, IDA5, IDA4 Plus,
IDA5
Calibration parameters: Flow rate, Flow Volume, Pressure
NIBP Analyzer Calibration

pressure: 0 to 500mmHgCalibration parameters: Pressure, leak rate
O T Lamp, Light Sources Calibration

Calibration of all ranges

Lux Measurement
O2 Analyzer Calibration

21% and 100% of O2

Calibration of Fluke Max O2
Pacemaker Analyzer Calibration

Resistance: 0 to 1500ohmCalibration of Fluke Sigmapace1000
Calibration parameters: Voltage, Resistance, Current
Pacemaker Calibration

Calibration of all ranges

Demand and asynchronous Mode

Patient Monitors Calibration

Calibration of all ranges

ECG, Spo2, NIBP, respiration, Electrical safety

Phototherapy Calibration

Calibration of all ranges

Temperature Calibration, Electrical safety

Physiotherapy Equipment Calibration

Calibration of all ranges

Electrical safety

Pulse Oximeters Calibration

Calibration of all rangesSpo2, Electrical safety
SPo2 Functional Tester Calibration

SPO2: 30 to 100%Calibration of Fluke Index 2
Spo2 Verification

SPO2: 30 to 100%

Oxygen Saturation verification

Syringe Pumps and Infusion Pumps Calibration

Calibration of all ranges

Flow, Occlusion, PCA Bolus, Volume, Electrical safety Test

Tourniquets Calibration

Calibration of all ranges

Pressure calibration
Ventilator Calibration and Anesthesia Machine Calibration

Calibration of all ranges

Electrical safety and 21 Ventilator Parameter like Tidal volume, I: E Ratio, Rate, PEEP etc.
Warmers and Patient Incubators Calibration

Calibration of all ranges

Temperature Calibration