Medical Equipment Calibration
Medical Equipment Calibration
Medical Equipment Calibration is the process of configuring the measurement and the accuracy of the medical device or the medical system used in Hospitals. This field intends to offer advance healthcare treatment, including diagnosis, monitoring and therapy.
The medical calibration measurements, is important because they establish whether the medical devices are appropriate, according to the international standards or not. The calibration also helps to minimise misdiagnosis caused by poorly calibrated machine. It is very important to configure hospital systems, according to the standard calibration because these machines need to be absolutely accurate since it is a matter of life and death.
Offerings | Technical Specification | Description |
---|---|---|
BP Apparatus | All Ranges | Manometer and Leak test |
Defibrillator Calibration | Calibration of all ranges | Energy, ECG, Charging time and Electrical safety |
ECG Machines Calibration | Calibration of all ranges | HV testing, Leakage Current test, Earth Bond, Resistance |
Electrosurgical Diathermy (Cautery Machines) Calibration | Calibration of all ranges | Electrical safety test, ESU output Power, Current, Peak to peak voltage, crest factor |
Fetal Monitor Calibration | Calibration of all ranges | Electrical safety and IUP |
Hemotherm Calibration | Calibration of all ranges | Temperature Calibration |
Incubator Analyzer Calibration | Humidity: 30 to 90 %RH Sound Level: 94 dB Temperature: 10 to 50 °C | Calibration of Fluke INCU-2 Calibration parameters Pressure, Flow rate, TIME, Temperature, RH, Airflow |
Infusion Pump Analyzer Calibration | Flow Rate: 10 ml/hr. to 1000 ml/hr. Flow Volume: 5 ml to 400 ml | Calibration of Fluke IDA1-S, IDA4, IDA5, IDA4 Plus, IDA5 Calibration parameters: Flow rate, Flow Volume, Pressure |
NIBP Analyzer Calibration | pressure: 0 to 500mmHg | Calibration parameters: Pressure, leak rate |
O T Lamp, Light Sources Calibration | Calibration of all ranges | Lux Measurement |
O2 Analyzer Calibration | 21% and 100% of O2 | Calibration of Fluke Max O2 |
Pacemaker Analyzer Calibration | Resistance: 0 to 1500ohm | Calibration of Fluke Sigmapace1000 Calibration parameters: Voltage, Resistance, Current |
Pacemaker Calibration | Calibration of all ranges | Demand and asynchronous Mode |
Patient Monitors Calibration | Calibration of all ranges | ECG, Spo2, NIBP, respiration, Electrical safety |
Phototherapy Calibration | Calibration of all ranges | Temperature Calibration, Electrical safety |
Physiotherapy Equipment Calibration | Calibration of all ranges | Electrical safety |
Pulse Oximeters Calibration | Calibration of all ranges | Spo2, Electrical safety |
SPo2 Functional Tester Calibration | SPO2: 30 to 100% | Calibration of Fluke Index 2 |
Spo2 Verification | SPO2: 30 to 100% | Oxygen Saturation verification |
Syringe Pumps and Infusion Pumps Calibration | Calibration of all ranges | Flow, Occlusion, PCA Bolus, Volume, Electrical safety Test |
Tourniquets Calibration | Calibration of all ranges | Pressure calibration |
Ventilator Calibration and Anesthesia Machine Calibration | Calibration of all ranges | Electrical safety and 21 Ventilator Parameter like Tidal volume, I: E Ratio, Rate, PEEP etc. |
Warmers and Patient Incubators Calibration | Calibration of all ranges | Temperature Calibration |