There are many quality tests that textiles products go through before they come into the market. When it comes to the complexity of textile equipment calibration, it takes the expertise of a highly skilled calibration company to achieve the industry specifications. We calibrate the equipment’s/ machines that assure the operators to perform those tests with confidence. Our calibrations are essential for the machines providing high performance tests.
Offerings | Technical Specification | Description |
---|---|---|
Abrasion Tester Calibration | Weights 9 Kpa – 433 gms Weights 12 Kpa – 630 gms Inner Diameter – Pilling 24.0 mm Outer Diameter – Abrasion 60.5 mm RPM 47.5 Diameter of Sample Cutter 140 mm Diameter of Sample Cutter 38mm | Abrasion Tester Diameter of Sample Cutter Abrasion Tester Diameter of Sample Cutter Abrasion Tester Inner Diameter – Pilling Abrasion Tester Outer Diameter – Abrasion Abrasion Tester RPM Abrasion Tester Weights |
ASTM Impact Tester (Charpy) Calibration | All parameter calibration | NIST sample, Support Anvils set, and Charpy Striker must available in stock with customer. (ASTM Impact Tester (Charpy)) Pressure and Vacuum calibration |
Bursting Strength Tester Calibration | Pressure Gauge 124, 81, and 55.2 psi Inner Diameter 30.5 mm Calculation of test area 7.3 cm2 | Pressure Gauge Inner Diameter Calculation of test areaAccuracy (±) ≥ 80 ppm to 1000 ppm |
Crock meter Calibration | Rubbing downward force 918gm Diameter of finger peg 16mm | Diameter of finger, stroke length, counts and Mass Digital Pressure gauge, Indicator, Controller, Transmitter (Hydraulic and Pneumatic) |
Dura Wash Calibration | Temperature 40, 50, 60°C Timer 15 min | Temperature Timer |
Electrolux Dryer Test Cycle Calibration | Test Cycle 90Min Exhaust Temperature 80°C Cool down 1min | Test Cycle Exhaust Temperature Cool down |
Govmark Flammability Tester Timer Calibration | 1 sec | Govmark Flammability Tester Timer Calibration |
Perspirometer Weights Calibration | 3.17 Kg and 3.61 kg | Weights calibration |
Pilling Tester Calibration | Pilling tube (mass) 10 gm Dimension of pilling tube 15x2mm | Pilling tube (mass) Dimension of pilling tube |
TEAR TESTER Calibration | Distance between clamping jaws 2.8mm Specimen tearing tester 15mm Pendulum with weight 3200, 6, 1600, 400gm | Distance between clamping jaws Specimen tearing tester Pendulum with weight |
Tumble Dryer Calibration | Time 60Min Temperature Cotton Sturdy 66 °C Delicate < 60°C Permanent 66°C | Time and Temperature Calibration |
Universal wear Tester Stroke motion Calibration | 115rpm | Speed Calibration |
Vertical Flammability Tester Timer Calibration | 5, 10 Sec | Time calibration by Comparison Method |
Washer /Washing Machine/Dryer Calibration | Washer Agitating Speed Normal cycle – 179 spm Washer Agitating Speed Delicate cycle - 119 spm Washer Agitating Speed Permanent cycle – 179 spm Washer Final Spin Speed Time Normal cycle – 6 min Washer Final Spin Speed Time Delicate cycle – 4 min Washer Final Spin Speed Time Permanent Cycle – 4 min Washer Spinning Speed of Washer Normal cycle – 645 rpm Washer Spinning Speed of Washer Delicate cycle – 430 rpm Washer Spinning Speed of Washer Permanent cycle – 430 rpm | Washer Agitating Speed Washer Final Spin Speed Time Washer Spinning Speed of Washer |
Wira Steam Timer Calibration | 30 sec | Time calibration by Comparison Method |
Wrist action Shaker Temperature Calibration | 35, 50, 70°C | Temperature calibration |