Thermal Calibration
Fixed points are most accurate devices available for defining a temperature scale. Fixed point cells are designed to realize the liquid-solid equilibrium temperatures of certain high purity metal elements, for calibration of thermometers at ITS-90 fixed points.
Lawkim has facility to calibrate SPRT/PRT by primary method (fixed point cell). Apart from Lawkim offer calibration of various sensors, oven, autoclaves, chambers for temperature and humidity parameters and covering range (-) 196°C to +1200°C
We Calibrate SPRT/PRTS/ THERMOCOUPLES by fixed point cell for following points:
Offerings | Technical Specification | Description |
---|---|---|
J-Type | -100 °C to 750 °C | Using Universal calibrator by simulation method |
K-Type | -200 °C to 1350 °C | Using Universal calibrator by simulation method |
PT-100/ RTD | 50 °C to 490 °C | Using Universal calibration by simulation method |
R-Type | 200 °C to 1700 °C | Using universal calibrator by simulation method |
Humidity Chamber/ Environmental Chamber | 30% RH @25°C to 90% RH @25°C | Using Digital Hygrometer (Single Position Calibration) |
Temperature of Humidity controller/ Indicator with sensor/ Thermo Hygrometer | 15 °c to 45 °c | Using Digital Temp/ RH Indicator with sensor & Humidity Chamber (By Comparison Method) |
RTD / Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, Glass Thermometer, Digital Thermometer | > 50 °c to 200 °c | Using RTD with indicator Oil bath (By Comparison Method) |
RTD/ Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, Digital Thermometer | > 200 °c to 600 °c | Using R type thermocouple with indicator /Dry Block Furnace (By Comparison Method) |
RTD/ Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, Glass Thermometer, Digital Thermometer | -30 °c to 50 °c | Using RTD with indicator/ methanol liquid bath/oil bath - by comparison method |
Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, | > 600 °C to 1200 °C | Using R , Type thermocouple with indicator( Dry block furnace )-By comparison method |
Offerings | Technical Specification | Description |
---|---|---|
J-Type | -100 °C to 750 °C | Using Universal calibrator by simulation method |
K-Type | -200 °C to 1350 °C | Using Universal calibrator by simulation method |
PT-100/ RTD | 50 °C to 490 °C | Using Universal calibration by simulation method |
R-Type | 200 °C to 1700 °C | Using universal calibrator by simulation method |
Humidity Chamber/ Environmental Chamber | 30% RH @25°C to 90% RH @25°C | Using Digital Hygrometer (Single Position Calibration) |
Dry block Furnace / Muffle / Industrial Furnace-Single Position | 200 °C to 1200 °C | Using R , Type Thermocouple with Indicator- Single Position |
Dry Block Furnace/ Muffle Furnace/ Industrial Furnace –Thermal Mapping -9 Point ( Multi position) | > 600 °C to 1200 °C | Using Data logger with N-Type Thermocouple -9 point. |
Dry Block Furnace/ Muffle Furnace/ Industrial Furnace –Thermal Mapping -9 Point ( Multi position) | >300 °C to 600 °C | Using Data Logger With N Type Thermocouple-9 Point |
Environment Chamber, Furnaces, Freezers, Oven, Vacuum Oven, BOD Incubator, Incubator, Centrifuge Chamber, Cold Room, Hot Room, Autoclave, Aging Oven-Single Position | (-)80 °C to 300 °C | Using PT-100X1 Simplex , 4 Wire RTD sensor with indicator-Single Position |
Environment Chamber, Furnaces, Freezers, Oven, Vacuum Oven, BOD Incubator, Incubator, Centrifuge Chamber, Cold Room, Hot Room, Autoclave, Aging Oven-Thermal Mapping 9 Points | -30 °C to 300 °C | Data logger with RTD sensors (Multi position -9 Points) |
RTD / Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, Glass Thermometer, Digital Thermometer | > 50 °c to 200 °c | Using RTD with indicator Oil bath (By Comparison Method) |
RTD/ Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, Digital Thermometer | > 200 °c to 600 °c | Using R type thermocouple with indicator /Dry Block Furnace (By Comparison Method) |
RTD/ Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, Glass Thermometer, Digital Thermometer | -30 °c to 50 °c | Using RTD with indicator/ methanol liquid bath/oil bath - by comparison method |
Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, | > 600 °C to 1200 °C | Using R , Type thermocouple with indicator( Dry block furnace )-By comparison method |