Thermal Calibration

Thermal Calibration

Fixed points are most accurate devices available for defining a temperature scale. Fixed point cells are designed to realize the liquid-solid equilibrium temperatures of certain high purity metal elements, for calibration of thermometers at ITS-90 fixed points.

Lawkim has facility to calibrate SPRT/PRT by primary method (fixed point cell). Apart from Lawkim offer calibration of various sensors, oven, autoclaves, chambers for temperature and humidity parameters and covering range (-) 196°C to +1200°C

We Calibrate SPRT/PRTS/ THERMOCOUPLES by fixed point cell for following points:

  • Liquid Nitrogen (-196.075 °C) CMC: 0.0084°C
  • Triple Point of Water (0.01°C) CMC: 0.0018°C
  • Freezing Point of Indium (156.598°C) CMC: 0.0030°C
  • Freezing Point of Tin (231.928°C) CMC: 0.0032°C
  • Freezing Point of Zinc (419.527°C) CMC: 0.0046°C
  • Freezing Point of Zinc (419.527°C) CMC: 0.0046°C

View our offerings

OfferingsTechnical SpecificationDescription
J-Type-100 °C to 750 °CUsing Universal calibrator by simulation method
K-Type-200 °C to 1350 °CUsing Universal calibrator by simulation method
PT-100/ RTD

50 °C to 490 °C
Using Universal calibration by simulation method
R-Type200 °C to 1700 °CUsing universal calibrator by simulation method
Humidity Chamber/ Environmental Chamber30% RH @25°C to 90% RH @25°CUsing Digital Hygrometer (Single Position Calibration)
Temperature of Humidity controller/ Indicator with sensor/ Thermo Hygrometer15 °c to 45 °cUsing Digital Temp/ RH Indicator with sensor & Humidity Chamber (By Comparison Method)
RTD / Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, Glass Thermometer, Digital Thermometer> 50 °c to 200 °cUsing RTD with indicator Oil bath (By Comparison Method)
RTD/ Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, Digital Thermometer> 200 °c to 600 °cUsing R type thermocouple with indicator /Dry Block Furnace (By Comparison Method)
RTD/ Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge, Glass Thermometer, Digital Thermometer-30 °c to 50 °cUsing RTD with indicator/ methanol liquid bath/oil bath - by comparison
method
Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature Transmitter, Temperature Gauge,> 600 °C to 1200 °CUsing R , Type thermocouple with indicator( Dry block furnace )-By comparison method

SITE FACILITY

OfferingsTechnical SpecificationDescription
J-Type-100 °C to 750 °CUsing Universal calibrator by simulation method
K-Type-200 °C to 1350 °CUsing Universal calibrator by simulation method
PT-100/ RTD50 °C to 490 °CUsing Universal calibration by simulation
method
R-Type200 °C to 1700 °CUsing universal calibrator by simulation method
Humidity Chamber/ Environmental Chamber30% RH @25°C to 90% RH @25°CUsing Digital Hygrometer (Single Position Calibration)
Dry block Furnace / Muffle / Industrial
Furnace-Single Position
200 °C to 1200 °CUsing R , Type Thermocouple with
Indicator- Single Position
Dry Block Furnace/ Muffle Furnace/ Industrial Furnace –Thermal Mapping -9 Point ( Multi position)> 600 °C to 1200 °CUsing Data logger with N-Type Thermocouple -9 point.
Dry Block Furnace/ Muffle Furnace/ Industrial Furnace –Thermal Mapping -9 Point ( Multi position)>300 °C to 600 °CUsing Data Logger With N Type Thermocouple-9 Point
Environment Chamber, Furnaces, Freezers,
Oven, Vacuum Oven, BOD Incubator, Incubator, Centrifuge Chamber, Cold Room, Hot Room, Autoclave, Aging Oven-Single Position
(-)80 °C to 300 °CUsing PT-100X1 Simplex , 4 Wire RTD sensor with indicator-Single Position
Environment Chamber, Furnaces, Freezers,
Oven, Vacuum Oven, BOD Incubator, Incubator, Centrifuge Chamber, Cold Room, Hot Room, Autoclave, Aging Oven-Thermal Mapping 9 Points
-30 °C to 300 °CData logger with RTD sensors (Multi position -9 Points)
RTD / Thermocouples With or without Controller
/ Indicator/ Data Logger / Recorder, Temperature
Transmitter, Temperature Gauge, Glass Thermometer, Digital Thermometer
> 50 °c to 200 °cUsing RTD with indicator Oil bath (By Comparison Method)
RTD/ Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature
Transmitter, Temperature Gauge, Digital Thermometer
> 200 °c to 600 °cUsing R type thermocouple with indicator /Dry Block Furnace (By Comparison Method)
RTD/ Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature
Transmitter, Temperature Gauge, Glass Thermometer, Digital Thermometer
-30 °c to 50 °cUsing RTD with indicator/ methanol liquid bath/oil bath - by comparison method
Thermocouples With or without Controller / Indicator/ Data Logger / Recorder, Temperature
Transmitter, Temperature Gauge,
> 600 °C to 1200 °CUsing R , Type thermocouple with indicator( Dry block furnace )-By comparison method